Speaker cable calculator: which gauge to use for your run
Work out the loss in decibels of your speaker cable from its length, cross-section and the speaker impedance, and the gauge you need to stay within 0.5 dB.
Drag the point to change the length, or use the arrow keys. Bands: up to 0.5 dB (recommended), up to 1 dB and over 1 dB.
Results
−0.21 dB
Excellent
With 39.4 ft (12.00 m) of 2.08 mm² (≈ 14 AWG) cable and 8 Ω speakers you lose 0.21 dB, and 2.4% of the power stays in the cable. That is within the recommended range (up to 0.5 dB).
- Cable resistance
- 0.199 Ω
- round trip, copper at 20 °C
- Power that stays in the cable
- 2.4%
- of the total the amplifier delivers
- Minimum size for 0.5 dB
- 0.88 mm²
- Off the shelf: 1 mm² or 16 AWG
- Maximum length for 0.5 dB
- 93.8 ft (28.59 m)
- with 2.08 mm² (≈ 14 AWG)
Planning the audio wiring for your home?
We integrate multiroom audio and home theater, with the rack and cabling documented from the plans. Tell us about your project and we will advise you.
Estimate for guidance. The final design is set by measuring the room on site.
When the amplifier sits in the technical rack and the speakers are 30, 60 or 100 feet away, the cable stops being a detail. The calculator above tells you how much signal you lose based on the length, the cross-section and the speaker impedance, and which size you need to stay within the recommended range.
How to use the calculator
- Enter the length of a single run, from the amplifier output to the speaker. The calculator already counts the trip out and back.
- Pick the impedance of your speakers (4, 6 or 8 Ω). It is usually on the label or the data sheet.
- Enter the cross-section of the conductor in mm², or pick an AWG gauge with the shortcuts.
- Read the loss in dB and the band it falls in. Drag the point on the chart to see how it changes with length: each gray curve is an AWG gauge.
- Copy the link to share the result with whoever installs the system.
What the loss measures, and why 0.5 dB
The cable has resistance and sits in series with the speaker: part of the voltage stays in the cable and never reaches the speaker. That loss is measured in decibels. At 3 dB, the speaker receives half the power it would get without the cable.
The calculator uses 0.5 dB as a practical target. It corresponds to the round-trip resistance of the cable staying below about 6% of the speaker impedance; some guides ask for under 5%. It is an installer’s reference, not a standard. Between 0.5 and 1 dB the loss is barely noticeable and a larger size is worth it; above 1 dB you should change the size or shorten the run.
Minimum size to stay within 0.5 dB
The “off the shelf” figure is the common metric size (or the even AWG gauge) just above the minimum.
| Length | 8 Ω speakers | 4 Ω speakers |
|---|---|---|
| 16.4 ft (5 m) | 0.36 mm² → 0.5 mm² (20 AWG) | 0.73 mm² → 0.75 mm² (18 AWG) |
| 32.8 ft (10 m) | 0.73 mm² → 0.75 mm² (18 AWG) | 1.45 mm² → 1.5 mm² (14 AWG) |
| 49.2 ft (15 m) | 1.09 mm² → 1.5 mm² (16 AWG) | 2.18 mm² → 2.5 mm² (12 AWG) |
| 65.6 ft (20 m) | 1.45 mm² → 1.5 mm² (14 AWG) | 2.91 mm² → 4 mm² (12 AWG) |
| 98.4 ft (30 m) | 2.18 mm² → 2.5 mm² (12 AWG) | 4.36 mm² → 6 mm² (10 AWG) |
| 131.2 ft (40 m) | 2.91 mm² → 4 mm² (12 AWG) | 5.82 mm² → 6 mm² |
Loss of the most common sizes
Values in dB, copper at 20 °C:
| Size | Impedance | 10 m | 20 m | 30 m |
|---|---|---|---|---|
| 1.5 mm² | 8 Ω | 0.25 | 0.49 | 0.72 |
| 1.5 mm² | 4 Ω | 0.49 | 0.95 | 1.38 |
| 2.5 mm² | 8 Ω | 0.15 | 0.29 | 0.44 |
| 2.5 mm² | 4 Ω | 0.29 | 0.58 | 0.86 |
| 4 mm² | 8 Ω | 0.09 | 0.19 | 0.28 |
| 4 mm² | 4 Ω | 0.19 | 0.37 | 0.54 |
What else matters
- Material. The calculator assumes copper. Copper-clad aluminum (CCA) has more resistance, so it would need a larger size.
- Temperature. Values are at 20 °C. If the cable runs through a hot duct, the resistance rises a little.
- Connections. Terminals that are tight and clean. A loose connection adds resistance this calculator cannot see.
- Past the target. Below 0.5 dB, going to a larger size adds little and makes the cabling more expensive.
How it is calculated
- Cross-section of an AWG gauge: diameter
d = 0.127 mm · 92^((36 − n) / 39)and areaA = π/4 · d². - Round-trip resistance:
Rc = ρ · 2L / A, withρ = 0.017241 Ω·mm²/m(copper at 20 °C) andLthe length of a single run. - Voltage loss at the speaker:
dB = 20 · log10((Z + Rc) / Z), withZthe impedance. - Power that stays in the cable:
Rc / (Rc + Z). - Minimum size for a loss target:
A = ρ · 2L / (Z · (10^(dB/20) − 1)).
As a cross-check, the 100-foot loss table published by ProSoundWeb agrees with this calculator within 0.1 dB; the table uses somewhat higher resistances than the 20 °C values. For the AWG formula, see American wire gauge.
Frequently asked questions
Which gauge for a 50-foot run?
With 8 Ω speakers, 1.5 mm² (16 AWG) is enough. With 4 Ω speakers, 2.5 mm² (12 AWG) keeps you within 0.5 dB.
Does length or gauge matter more?
They weigh the same: resistance grows with length and drops with cross-section. Doubling the length requires doubling the cross-section to keep the same loss.
Do 4 Ω speakers need more cable?
Yes. The same cable resistance weighs twice as much against 4 Ω as against 8 Ω, and the loss in dB is roughly double.
Does it work for a subwoofer cable?
No. Powered subwoofers connect with a signal cable (RCA or XLR). This calculator is for passive speakers connected to an amplifier.
Want the wiring done right from the start?
At DomuLab we integrate multiroom audio and home theater, with the rack and cabling documented from the plans. If you already have the distances for your project, tell us and we will advise you. To see how audio spreads through the whole house, read the guide to multiroom audio and video and our audio and video service.